This guide demonstrates the process of upgrading an Aura or TD-1050 screen from Android version 5.1 to Android version 7.1.
...
Now the required firmware files must be copied onto the root of each USB drive as indicated below:
USB Drive 1#1 | blackwidow-lollipop-v1.1.0-2019_06_23-13_13_24-d.zip |
---|---|
USB Drive 2#2 | TD-1050_7.1.1.img |
Warning |
---|
Do Please do not unzip the firmware file as this will cause the upgrade procedure to fail. |
Warning |
---|
Please do not rename the TD-1050_7.11.img file. |
...
Exiting the ResourceXpress application
When an Aura or TD-1050 screen first boots up it by default will launch the ResourceXpress Android client application. In order to check what version of firmware the device is currently running, you will need to exit the app. This is done in the following manner:
Step 1: Tap the four corners of the screen in a clockwise direction, starting from the top left.
...
Step 2: Enter the PIN code in the pop-up box and then click OK.
Info |
---|
By default, the PIN code is 11223344. |
...
Step 3: Tap on the options button (displayed as three dots) at the top right of the screen, then select Quit.
...
Step 4: The secondary security screen will now appear. Enter the PIN code and select Unlock.
Info |
---|
By default, the PIN code is 11223344. |
...
Step 5: Under Settings in the bottom right corner, check which FW Ver: is displayed.
...
If the firmware version shown is a lower version than v1.1.0, then proceed with USB drive one#1.
If the firmware version shown is v1.1.0, then skip to using USB drive two#2.
If the firmware version shown is v2.0.0, then no upgrade is necessary on this device.
Upgrading to v1.1.0 - USB drive
...
#1
Step 1: Insert USB drive one #1 into the device.
Step 2: Tap on Settings in the bottom right corner.
...
Step 3: Scroll down to Firmware update and select it.
...
Step 4: Tap on Firmware update.
...
Step 5: Tap on the START FIRMWARE UPDATE button at the bottom of the screen
...
Step 6: The device will then reboot. When it starts up again, an Android logo will be visible on the screen and the front LED will begin blinking red. Wait for the Installing system update… progress bar to complete.
Step 7: Once the screen turns back on it will return to the ResourceXpress application. Repeat the previous steps on Exiting the ResourceXpress application and then verify what firmware version is now displayed under Settings. It should now say FW Ver: RX7_v1.1.0.
...
Upgrading v1.1.0 to v2.0.0 - USB drive
...
#2
Note |
---|
Performing this upgrade will factory reset the device. Please be sure to make a note of the screen URL and any other custom settings before proceeding. |
Step 1: Insert USB drive two #2 into the device.
Step 2: Tap on Settings in the bottom right corner.
...
Step 3: Scroll down to Firmware update and select it.
...
Step 4: Tap on Firmware update.
...
Step 5: Tap on the UPGRADE TO VERSION 7.1.1 button at the bottom of the screen
...
Step 6: The device will then reboot. When it starts up again, an Android logo will be visible on the screen and the front LED will show steady amber. Wait for the Installing system update… progress bar to complete.
Info |
---|
This process will take longer than the previous upgrade and the screen may reboot several times. |
Step 7: Once the screen turns back on it will return to the ResourceXpress application. Repeat the previous steps on Exiting the ResourceXpress application and then verify what firmware version is now displayed under Settings. It should now say FW Ver: RX12_U_v2.0.0.
...
As the upgrade from Android 5.1 to Android 7.1 restores the ResourceXpress client application to factory settings, this will now need to be re-entered.
Step 1: To return to the ResourceXpress application, press PLAY.
Step 2: A blue screen stating “Resource Information Unavailable” will now be displayed. Tap the four corners of the screen in a clockwise direction, starting from the top left.
...
Step 3: Enter the PIN code and press OK.
Info |
---|
By default, the PIN code is 11223344. |
...
Step 4: Tap the options button (displayed as three dots) in the top right corner, then select Screen URL.
...
Step 5: Re-enter the ResourceXpress profile URL for this screen. The “server” text must be replaced by the ResourceXpress server FQDN or IP address, and the “.aspx” section must be instead changed to “.html” in order to accommodate the latest Astro stylesheet. Finally, the ID number must be changed to the relevant ID number for the meeting room screen you wish to be displayed. An example is shown in the screenshot below. Once this is done, click Save.
...